Sign In | Join Free | My burrillandco.com
Home >

10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine

    Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers
     
    Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers
    • Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers
    • Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers
    • Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers
    • Buy cheap 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine from wholesalers

    10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine

    Ask Lasest Price
    Brand Name : Covidien
    Model Number : 10097559 PSR-11-75-KE13PB
    Payment Terms : T/T, Western Union,Paypal
    Delivery Time : 3-5 working days
    MOQ : One piece
    • Product Details
    • Company Profile

    10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine

    10097559 PSR-11-75-KE13PB oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


    Oxygen sensor calibration test


    Test the oxygen sensor calibration as follows:


    1. Connect the ventilator oxygen tubing to a known source of 100% O2 (e.g., a medical oxygen cylinder). Press the 100% O2/CAL button for 2


    minutes or the INCREASE O2 button for 2 minutes to calibrate the oxygen sensor. Once the button light turns off, proceed to the next step.


    2. Connect the ventilator oxygen tubing to another known source of 100% O2 (e.g., a second medical oxygen cylinder).


    3. Set %O2 to the following values ​​and wait one minute for each monitored value to stabilize: 21% 40% 90%


    4. Observe the upper display to ensure that the O2 value (% O2 delivered) is within 3% of each setting within one minute of selecting each


    setting.


    Oxygen Sensor Calibration Button: Older ventilators use the 100% O2/CAL 2 minutes button, while newer ventilators use the INCREASE O2 2


    minutes button. Provides 100% oxygen (if available) for two minutes and calibrates the oxygen sensor. The green light on this button will


    illuminate and a message (100% O2 Cal in Progress) will appear on the lower touchscreen to indicate 100% O2 delivery is active. If you press the


    O2 button again, the system will restart the two-minute delivery interval. Press CANCEL to stop calibration. For information on calibrating the


    oxygen sensor, see page TR 15-5.


    Alarm Messages


    If you see this O2 Sensor message, it means that background checks have identified a problem with the oxygen sensor (sensor error or not calibrated). Patient ventilation will not be affected. And you can:


    • Press 100% O2 CAL or O2 INCREASE for 2 minutes to recalibrate the oxygen sensor.


    • Disable the oxygen sensor.


    • Replace the oxygen sensor.


    Specification of 10097559 PSR-11-75-KE13PB oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


    Product Name

    PSR-11-75-KE13PB 10097559 oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


    BrandCovidien
    Part No

    PSR-11-75-KE13PB 10097559


    Application

    PB760 PB840 PB980 Puritan Bennett Ventilator Machine


    MOQOne piece
    ConditionOriginal /Compatible new
    Warranty90 days

    Photo


    Below photo is PSR-11-75-KE13PB 10097559 oxygen sensor ,which can be used for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine .For more details ,please feel free to contact us .



    Thank you so much for your attention .If you're interested in 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine ,feel free to contact us .Thank you .

    Quality 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Patient Monitor Accessories products from this supplier
    Inquiry Cart 0