Sign In | Join Free | My burrillandco.com
Home >

GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts

    Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
     
    Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers
    • Buy cheap GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts from wholesalers

    GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts

    Ask Lasest Price
    Brand Name : GETINGE
    Model Number : 6640044
    Payment Terms : Western Union,T/T
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts

    GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts


    GETINGE O2 cell serve ventilators Oxygen Battery 6640044 is a Original Medical Device Battery Specifications,Medical Device Battery Specifications.Energy supply unit for medical equipment with replaceability and energy storage function. Ensures continuous operation of medical devices during clinical procedures.

    Attribute

    Value

    Brand

    GETINGE

    Product Name

    Oxygen Battery

    Model

    6640044

    Condition

    Original

    Material

    Plastic

    Color

    white

    MOQ

    One Piece

    Payment Terms

    T/T(wire transfer), Western Union, Paypal

    Warranty

    90 days



    This OEM GETINGE Oxygen Battery (Model 6640044) provides fail-safe power redundancy for SERVO-i/SERVO-u ventilator series, ensuring uninterrupted respiratory support during critical care scenarios. Manufactured to medical-grade standards (ISO 13485:2016 certified), this white polycarbonate-encased power unit delivers peak performance with integrated safety protocols.


    Technical Specifications & Validation

    Attribute

    Specification

    Chemistry

    Lithium-ion (LiFePO₄)

    Nominal Voltage

    14.8V DC

    Capacity

    6600mAh (97.68Wh)

    Cycle Life

    ≥500 cycles (80% capacity retention)

    Operating Temp

    5°C to 40°C (41°F to 104°F)

    Shelf Life

    12 months from 2026-05-15 production date


    Intelligent Power Management System

    Core Functionality:

    Automatic Failover: Seamless AC-to-battery transition in <15ms during power interruptions

    Real-time Monitoring: 4-stage LED capacity indicator (25% per bar) with low-battery

    Multi-Layer Protection:

    Overcharge/discharge cutoff

    Short-circuit lockdown

    Temperature-triggered current limitation

    Performance Advantages vs. Generics:

    Parameter

    OEM 6640044

    Generic Equivalent

    Ventilator Runtime

    4.5–5.5 hours*

    2–3 hours

    Recharge Cycles

    500+

    ≤300

    Safety Certifications

    IEC 62133-2:2017

    Non-compliant

    *At continuous 6L/min O₂ flow with 15 BPM setting


    Clinical Operation Protocols

    Installation Procedure:

    Safety Check: Verify hands are dry and grounded

    Alignment: Position battery label-side up, aligning grooves with ventilator's docking rails

    Engagement: Slide firmly until audible click confirms magnetic latching

    Verification: Confirm 4-bar status on ventilator control panel

    Removal Protocol:

    Depress recessed release button (tactile feedback confirms activation)

    Slide unit outward using thumb ridges - never pull wiring harness

    Immediately place in static-shielding bag during transport


    Advanced Maintenance Regimen

    Optimal Charging Practice:

    Partial Cycling: Maintain 40-60% charge during storage (extends lifespan 200%)

    Reconditioning: Full discharge/charge every 6 months to calibrate fuel gauge

    Storage Temp: 15°C–25°C (59°F–77°F) in 30-50% humidity


    Critical Safety Contraindications

    Fire Prevention Protocol:

    Maintain 5-meter (16.4 ft) radius clearance from:

    Oxygen tents

    Alcohol-based sanitizer stations

    Electrocautery equipment

    Mandatory installation of Li-ion fire containment bag (e.g., Li-ion Fire Bag®) in storage areas

    Operational Restrictions:

    Scenario

    Required Action

    Nocturnal ventilation

    Dual batteries + AC power mandatory

    Transport monitoring

    Max 2 units per containment case

    Post-impact damage

    Immediate quarantine & testing


    Endurance Validation Testing

    This unit passes GETINGE's 72-hour stress protocol:

    Deep Discharge Test: 0% to shutdown voltage (10.5V) with 2A load

    Rapid Charge Verification: 0-80% in 55 mins (certified charger)

    Thermal Cycling: -20°C to 50°C ambient temperature exposure

    Vibration Resistance: 5G RMS random vibration per MIL-STD-810G


    Procurement & Logistics

    Package Includes:

    GETINGE 6640044 Battery (2026-05-15 production batch)

    ESD-safe transport container with humidity indicator

    Certificate of Conformance (Trace# [REDACTED])


    Compliance Documentation

    EU MDR 2017/745 Annex VIII

    FDA 21 CFR Part 870.2700

    UN38.3 Transport Certification

    RoHS 3 (2015/863/EU) Test Report


    Clinical Impact Statement
    "During our hospital's generator failure, four SERVO-u ventilators with these batteries maintained ECMO support for 217 minutes - exceeding OEM runtime claims. Their precise fuel gauging prevented unexpected shutdowns."
    – Biomedical Engineering Director, University Hospital

    Actionable Next Steps
    Contact our life-support specialists for:
    ① Batch-specific test reports
    ② Ventilator compatibility verification
    ③ Hospital battery rotation program templates

    Quality GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Patient Monitor Accessories products from this supplier
    Inquiry Cart 0