Sign In | Join Free | My burrillandco.com
Home > General Industrial Equipment Design Services >

High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower

    Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers
     
    Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers
    • Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers
    • Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers
    • Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers
    • Buy cheap High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower from wholesalers

    High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower

    Ask Lasest Price
    Brand Name : XIANRUN BLOWER
    Model Number : ZR-HP SERIES
    Certification : CE, ISO 9001
    Price : 50-50000
    Payment Terms : L/C, D/A, D/P, T/T
    Supply Ability : 10000
    Delivery Time : 5-45DAYS
    • Product Details
    • Company Profile

    High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower

    High pressure dc blower low noise blower high efficiency blower industrial blower fans regenerative air blower

    Installation, commissioning and operation
    1. Before installation:

    All the components of the fan should be comprehensively inspected, such as: whether the mechanical parts are complete, whether the rotation direction of the impeller and the casing is consistent, whether the connection of each part is close, whether the main mechanical parts such as the impeller, spindle, bearing are damaged, and whether the transmission group is flexible, etc., if the problem is found, it should be repaired immediately.

    2. When installing:

    Pay attention to check the casing, there should be no tools or debris dropped and left in the shell. In order to prevent rust and reduce disassembly difficulties, a layer of lubricating oil or mechanical oil should be coated on some bonding surfaces. The connection surface between the fan and the foundation and the inlet and exit pipelines should be adjusted to make them coincide naturally. The connection should not be forced, and the weight of the pipeline should not be added to the components of the fan, and attention should be paid to ensure the horizontal position.

    3. Installation requirements:

    (1) Install according to the position and size shown in the drawing. In order to ensure high efficiency, especially ensure the axial and radial clearance size of the air inlet and the impeller.

    (2) After installation, try to dial the transmission group to check whether there is too tight or scratches with the fixed part. If not, it should be excluded.

    (3) Test operation of fan:

    After all installation is completed, the test run can only be carried out after the general inspection is qualified.

    The power selected by the fan refers to the specific working condition, coupled with mechanical loss and the due safety factor, in order to prevent the motor from being burned due to overload, the fan must be started and tested in the absence of load, namely: Will go to adjust the door closed, wind the wind door slightly open for tuning section, such as no vibration, peculiar smell, sound, and the abnormal phenomenon such as leakage, leakage, leakage, then step by open gate, to the provisions of the conditions, in the process of operation should strictly control current, shall not exceed bid, bearing temperature rise Shall not be more than 40 oc, temperature is not more than 70 c.


    Key Features

    • Impeller diameter: 90~3500 mm
    • Speed of mainshaft: 560~2900 rpm
    • Pressure range: 3000~25425 Pa
    • Flow range: 1297~43305 m3/h
    • Air Temperature: 20~1000 Celsius degree
    • Material: Cast Iron, Carbon Steel, Stainless Steel.

    • Efficiency: 70%-90%

    Applications

    • Cement
    • Industrial boiler
    • Power generation
    • Chemical processing
    • Combustion-support
    • Cooling systems
    • Corrosive gas
    • Dryer
    • Dust collection
    • Forced draft
    • Fume exhaust
    • General ventilation
    • Incineration
    • Induced draft

    Quality High Efficiency Centrifugal Fans , 2900rpm High Pressure Regenerative Air Blower for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Henan Xianrun Blower CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more High Pressure Centrifugal Blower products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0