    Brand Name : KACISE
    Model Number : KMPI-A
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    KMPI - A Type Capillary Electrophoresis Electrochemiluminescence Detector

    KMPI - A Type Capillary Electrophoresis Electrochemiluminescence Detector


    Product Introduction


    The KMPI - A type capillary electrophoresis electrochemiluminescence detector is a high - performance analytical testing device based on the Windows operating platform. This instrument can perform chemiluminescence detections such as static injection chemiluminescence, capillary electrophoresis chemiluminescence, and capillary electrophoresis electrochemiluminescence, and can also be used as an electrochemical workstation independently.


    Applications

    • Detection and analysis of drugs, amino acids, polypeptides, proteins, and nucleic acids.
    • Research on the interactions between proteins and drugs, as well as between proteins and nucleic acids.
    • The high - efficiency separation of capillary electrophoresis and the highly sensitive detection of chemiluminescence are well combined, realizing the integration of separation and detection of complex samples and greatly shortening the sample pretreatment time.
    • This instrument consists of four parts: an electrochemical analyzer, a multi - functional chemiluminescence detector, a numerical control capillary electrophoresis high - voltage power supply, and a multi - functional chemiluminescence detector.
    • The numerical control electrochemical analyzer is the core of the entire testing system. The instrument is internally integrated with a standard USB interface for communication with the system computer, which can effectively complete the data transmission between the system computer and the multi - channel data acquisition analyzer and corresponding control components.

    Technical Features

    Electrochemical Analyzer

    The electrochemical analyzer provides electrochemical methods such as potentiostat, cyclic voltammetry, and linear sweep required for electrochemical and electrochemiluminescence analysis, as well as electrochemical current detection means. This part is the core of the entire testing system. The instrument is internally integrated with a standard USB interface for communication with the system computer, which can effectively complete the data transmission between the system computer and other instruments and corresponding control components.


    Technical Specifications

    Potential Range: - 10 V to 10 V

    Current Range: ±250 mA

    Reference Electrode Input Impedance: 10 MΩ

    Sensitivity: 1 x 10⁻⁹ to 1 x 10⁻² A, a total of 8 ranges

    Input Bias Current: < 50 pA; Potential Increment: 1 mV

    Scan Rate: 0.001 to 65 V/S

    Multi - functional Chemiluminescence Detector

    Technical Specifications

    Measurement Dynamic Range: Greater than 5 orders of magnitude

    Measurement Accuracy: Better than 0.05%

    Amplifier Gain: 1×, 10×, 100×, 1000×

    Filter Frequency: 10 Hz, 20 Hz, 50 Hz, 100 Hz

    Amplifier Output Drift: Better than 0.05%

    Signal Noise: ≤ 0.5 mV (P - P value, 1×)

    Input Impedance: ≥ 10 MΩ

    Integrating Amplifier Integration Time: 0.001 to 10 seconds

    System Automatic Zero - setting

    Gain Automatic Control

    Sampling Rate: 1 to 200 times per second

    Numerical Control Capillary Electrophoresis High - voltage Power Supply

    It provides the high voltage required for capillary electrophoresis analysis and can independently control the injection time and injection high voltage, as well as the analysis time and analysis high voltage according to the program.


    Quality KMPI - A Type Capillary Electrophoresis Electrochemiluminescence Detector for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Detector Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0