Sign In | Join Free | My burrillandco.com
Home >

KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results

    Buy cheap KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results from wholesalers
     
    Buy cheap KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results from wholesalers
    • Buy cheap KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results from wholesalers

    KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KIFFM - E
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results

    Technical Parameters of KIFFM - E Flow Injection Chemiluminescence Analyzer


    Product Introduction


    The KIFFM - E flow injection chemiluminescence analyzer is the earliest fully - automatic chemiluminescence detection and analysis system launched in China. The instrument integrates a high - precision dual - peristaltic pump numerically - controlled wide - speed - regulation flow injection sampling system, an IFFS - A multi - functional ultra - weak chemiluminescence detector, and chemical spectrogram analysis software, and can perform analyses such as static injection chemiluminescence analysis and flow injection chemiluminescence.


    Application Fields

    • Research on static and flow injection photometric analysis
    • Flow injection on - line testing and analysis

    Technical Features


    • High - precision Peristaltic Pump Wide - range Digital Speed - regulation System
    • High - precision peristaltic pump wide - range digital speed - regulation system: Speed - regulation range 0 - 99 levels
    • Forward/reverse function can realize oscillation, mixing, separation, and extraction of solutions in pipelines
    • Pump - stop function can be used for slow - reaction analysis or for micro - sampling
    • Or achieve up to 10 - channel pipeline injection (5 channels/pump)
    • Can realize automatic dilution of solutions, with a maximum dilution ratio of 1:99
    • 16 - channel automatic/manual valve
    • Analysts can arbitrarily adjust the speed, running time, running direction, number of cycles, cycle starting point, positions of two injection valves, reading output, and termination step of the peristaltic pump
    • IFFS - A Multi - functional Chemiluminescence Detector
    • It can perform various luminescence detections such as static injection chemiluminescence, capillary electrophoresis chemiluminescence, and capillary electrophoresis electrochemiluminescence, and can also be used as a shield for electrochemical detection to shield the influence of external electromagnetic interference signals.

    Technical Specifications

    Input high voltage: - 100 to - 1000 V, stability: better than 0.01%

    Wavelength range: 300 - 650 nm (maximum response wavelength: 420 nm)

    SP > 1000 A/Lm, programmable high - precision negative high - voltage power supply and high - precision pre - amplifier, record analog signal output

    High - precision Data Acquisition System, Controlled by Computer, Capable of

    Gain control: 1X, 2X, 4X, 8X, 16X

    Filter cut - off frequency adjustment: 10 - 100 Hz

    Sampling rate: 1 - 100T/S

    Automatic/manual zero - setting

    External signal input interface, which can receive analog signals from other instruments, input range: 0 - 5V

    REMEX Fully Chinese - Language Data Analysis System

    The measurement system can complete the setting and control of sampler parameters, the setting and control of analysis parameters, real - time data acquisition of chemical reaction kinetics, and curve plotting. In the repeated measurement state, it can perform kinetic curve tests such as cumulative superposition and average superposition synchronously with the sampling system.

    Measurement and processing of measured spectrogram data: The value at any point of the measured spectrogram can be read. The effective area can be set for the waveforms at any two points of the measured spectrogram, and the area, peak value, valley value, and average value can be calculated. Abnormal points in the measured spectrogram can be removed one by one or in multiple points.


    Quality KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Detector Sensor products from this supplier
    Inquiry Cart 0