Sign In | Join Free | My burrillandco.com
Home >

20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection

    Buy cheap 20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection from wholesalers
     
    Buy cheap 20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection from wholesalers
    • Buy cheap 20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection from wholesalers

    20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection

    Ask Lasest Price
    Brand Name : Alphasense
    Model Number : CL2-B1/CL2-B1+
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection

    CL2-B1/CL2-B1+ Chlorine Sensor

    The CL2-B1 sensor is a PPM sensor that is designed for a broad variety of applications and instrumentation including portable gas detectors and fixed gas detection systems for industrial safety, environmental air quality and process control. This product is available in our standard format (CL2-B1) and with our patented Integrated Smart Technology (CL2-B1+) that has an IST board with a memory chip and temperature sensor integrated in the sensor. The + sensors store specific calibration, specification, and identification data on every sensor allowing plug and play operation. The on-board temperature sensor improves the accuracy and simplicity of temperature compensation algorithms.

    Sensor Data

    Performance

    Sensitivity Response time Zero current

    Resolution

    Range

    Linearity Overgas limit

    nA/ppm in 10ppm Cl2

    t90 (s) from zero to 10ppm Cl2 (33Ω load resistor) ppm equivalent in zero air

    RMS noise (ppm equivalent) (33Ω load resistor)

    ppm limit of performance warranty

    ppm error at full scale, linear at zero and 10ppm Cl2 maximum ppm for stable response to gas pulse

    -600 to -1150

    < 60

    ± 0.4

    < 0.02

    20

    < ± 0.2

    60


    Lifetime


    Zero drift Sensitivity drift

    Operating life


    ppm equivalent change/year in lab air

    % change/year in lab air, monthly test

    months until 80% original signal (24-month warranted)


    < 0.03

    < 6

    > 24

    Environmental

    Sensitivity @ -20°C Sensitivity @ 50°C

    Zero @ -20°C

    Zero @ 50°

    % (output @ -20°C/output @ 20°C) @ 10ppm

    % (output @ 50°C/output @ 20°C) @ 10ppm

    ppm equivalent change from 20°C

    ppm equivalent change from 20°C

    70 to 90

    90 to 105

    < 0 to 0.1

    < 0 to -1


    Cross Sensitivity


    H2S sensitivity NO2 sensitivity NO sensitivity

    SO2 sensitivity

    CO sensitivity

    H2 sensitivity C2H4 sensitivity NH3 sensitivity CO2 sensitivity


    % measured gas @ 20ppm H2S

    % measured gas @ 10ppm NO2

    % measured gas @ 50ppm NO

    % measured gas @ 20ppm SO2

    % measured gas @ 400ppm CO

    % measured gas @ 400ppm H2

    % measured gas @ 400ppm C2H4

    % measured gas @ 20ppm NH3

    % measured gas @ 5% (Vol) CO2


    < -300

    < 120

    < 1

    < -1

    < 0.1

    < 0.1

    < 0.1

    < 0.1

    0

    Key Specifications

    Temperature range Pressure range

    Humidity range

    Storage period

    Load resistor

    Weight

    °C

    kPa

    % rh continuous (see note below)

    months @ 3 to 20°C (stored in sealed pot)

    Ω (for optimum performance)

    g

    -20 to 50

    80 to 120

    15 to 90

    6

    33

    < 13

    IST Board Data

    Interface


    Communication Bus Max. Bus Speed Input Logic Levels

    Absolute Max. Input Signal

    Compatible with the 400 kHz I²C protocol Up to 1 MHz

    High (Recessive) < 2.3 V | Low (Dominant) < 0.2 V

    3.6 V


    Electrical


    Supply Voltage Range Supply current – Stand-By Supply current – Operating

    Power Supply Conditioning ESD Protection

    Bus Pins Input Capacitance

    1.7 V to 3.6 V

    < 5 μA

    < 0.15 mA (temperature reading only)

    < 2.15 mA (temperature reading + memory reading/writing) Built-In 100 nF decoupling capacitor

    4 kV (human body model) - Enhanced ESD / Latch-Up protection 15 pF max.


    Performance


    Operational Temperature Temperature Sensor Accuracy Memory Data Retention

    Memory Write Cycles

    –40 °C to +85 °C

    ±1°C (-0°C to +70°C)

    > 200 years

    > 4,000,000


    Data & Communication


    Memory IC & I2C Address Temperature IC & I2C Address Product Data Start Address Calibration Data Start Address User Data Area

    CRC Polynomial

    Digital Signature Algorithm

    M24128X-FCU | Device Address: R - 0xA0 / W – 0xA1 MAX31875R0TZS+T | Device Address: R - 0x90 / W – 0x91 0x0900

    0x0B00

    0x0D00 – 0x18FF (3,072 Bytes)

    0x 01 04C1 1DB7 SHA-256


    Quality 20 Range Resolution 0.02 CL2-B1/CL2-B1 Chlorine Sensor for Accurate Detection for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Detector Sensor products from this supplier
    Inquiry Cart 0