| Sign In | Join Free | My burrillandco.com |
|
...cable NO.7101112 Construction Parameters: Inner Conductor 13.10±0.10mm Smooth Copper Tube Insulation 32.30±0.25mm Foamed PE Outer Conductor 35.80±0.25mm Annular Corrugated Copper Tube Jacket 38.80±0.30mm PE,...
...cable NO.7101113 Construction Parameters: Inner Conductor 13.10±0.10mm Smooth Copper Tube Insulation 32.30±0.25mm Foamed PE Outer Conductor 35.80±0.25mm Annular Corrugated Aluminum Tube Jacket 38.80±0.30mm P...
...cable NO.7101114 Construction Parameters: Inner Conductor 17.30±0.15mm Corrugated Copper Tube Insulation 42.50±0.30mm Foamed PE Outer Conductor 46.50±0.20mm Annular Corrugated Copper Tube Jacket 49.50±0.30mm...
...cable NO.7101115 Construction Parameters: Inner Conductor 17.30±0.15mm Corrugated Copper Tube Insulation 42.50±0.30mm Foamed PE Outer Conductor 46.50±0.20mm Annular Corrugated Aluminum Tube Jacket 49.50±0.30...
... Characteristics: Rated voltage Uo/U: 6-35 KV. Allowable long-term working temperature of cable conductor: 90℃ Allowable temperature of cable conductor during short circuit (long duration no more than 5s): 2...
... Characteristics: Rated voltage Uo/U: 6-35 KV. Allowable long-term working temperature of cable conductor: 90℃ Allowable temperature of cable conductor during short circuit (long duration no more than 5s): 2...
.richtext [data-maya] { width: 750px; font-size:14px; } XGN2 China supplier indoor air insulated 11 KV 2000 AMPS switchgear Features Reasonable structure Good reliabilities and safety Easy to operate and mainta...
.richtext [data-maya] { width: 750px; font-size:14px; } XGN2 Directly factory sale industrial AC 10 kv switchgear Features Reasonable structure Good reliabilities and safety Easy to operate and maintain Product...
Cble HTA CIS - 18/30KV (36KV) 3 x 150 mm Alu Application: The cable can be used for underground power transmission . The cable can bear external mechanical pressure and moderate pulling force with different d...
AL 100% XLPE TRXLPE 1/0 AWG Medium Voltage Concentric Cables Copper wire Metallic Screen Application: The xlpe single core concentric neutral cables rated 5 to 45KV which are used for the transmission and elect...
AL / CU 133% 15KV TRXLPE 500 MCM MV Concentric Cables with 1/3 neutral shielded Application: The xlpe single core concentric neutral cables rated 5 to 45KV which are used for the transmission and electrical ene...
MV xlpe insulated armoured electric 33kv copper cable Standard:IEC60502, BS6346, VDE, AS/NZS, UL,etc The Rated Voltage(kv): 1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 2nd class 1/1 3/3 6/6 8.7/10...
Single core and three cores cu/XLPE/CTS/LSOH /SWA/LSOHpower cable rated voltage 6/10(12)kV Detailed Product Description Constructions Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228 Conduct...
...Cables APPLICATION: Medium voltage aluminum power cable can be used for connections from existing grid to new sub-main developments. CONSTRUCTION: Conductor Stranded or Solid Aluminium Conductor Insulation X...
...Power Cable Low Voltage XLPE 3x150 mm²+2x95mm² CU/XLPE/SWA PVC Insulation For power station ,subway ,tunnel ,high-rise building,large industrial and mining enterprise,oil field,coal mine and other places of ...
...ble ARVFV 3x95mm²+50mm² Alu Steel Armour Power Cable TECHNICAL DATA SHEET Câble ARVFV 3x95mm²+50mm² Alu Item Description Unit Data 1 Standard IEC 60502-1 2 Size 3x95+50mm2 3 Rated Voltage kV 0.6/1 4 Phas...
...Souterrain Câble ARVFV 4x35mm² Alu Steel Armour Power Cable TECHNICAL DATA SHEET Câble ARVFV 4x35mm² Alu Item Description Unit Data 1 Standard IEC 60502-1 2 Size 4x35mm2 3 Rated Voltage kV 0.6/1 4 Cores ...
... XLPE Insulated Armored Power Cables Applicable standards: IEC60502, BS6622, SANS1339, AS/NZS1429.1, DIN VDE 0276-626, NFC 33-226, IEC60840, ICEA S-93-639. ICEA S-94-649 Production Scope: a) National standar...
..., 19H, 25 KV, 90°C, rotulación contrastante, semiconductora interna, aislación TR-XLPE, carrete 1000 mts, semiconductora externa, cinta higroscopica, ......
33KV 800mm2 XLPE Insulation Copper Aluminum Conductor MV Power Cable Can Direct Burial Standard: IEC60502, BS6346, VDE, AS/NZS, UL,etc The Rated Voltage(kv): 1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 ...