...current transformer 1000:1 0~10A sampling resistor 50Ω Features and application: Small size,high accuracy,food consistency,for current and power measurement Key words: current transformer Structural paramete...
.../42/75kV(10kV products),40.5/95/185kV(35kV products). Rated frequency:50Hz or 60Hz Rated secondary current :5A or 1A....
...current transformer Ultra-Micro PCB Mounting Current Transformer Features and applications: Small size,high accuracy,good consistency,for current and power measurement Structural parameters: Remarks: Primary...
... or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. Apply to current measurement, monitoring and protection for...
... resin casting type CT Technical data The current transformers are in accordance with GB20840.2 and IEC61869-2 standards Rated insulation level: 12/42/75kV Rated frequency: 50Hz or 60Hz Rated secondary curre...
... engineering, a current clamp. current probe is an electrical device having jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the...
... reconstruction projects. Technical parameter Model Name Current Ratio (Primary/Secondary) Accuracy Class Rated Load (VA) Perforation Hole Size (mm) AKH-0.66/K-φ10 5A/1.25mA 0.5 10 φ10 (10~20)A/5mA (40~60)A/...
...Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output parame...
...Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output parame...
Product details Multi-Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output Product Description ZXYZ-2002 Transformer On Load Tap Switch Tester is mainly used for measuring transformer on-lo...
...current transformer 100~400A motor protection isolation voltage 3000V Features and application: High accuracy, good consistency, for motor protection Structural parameter: Front view Lateral view The main te...
...current transformer D-type Ferrite Core Fixed joint CT 5A 1000T Imax 100A black case current transfromer Suitable for single-phase electricity meter as well as anti-tempering electricity meter Compact an...
Technical data The current transformers are in accordance with GB20840.2 and IEC61869-2 standards Rated insulation level: 40.5/95/185kV Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Ambient te...
...100-800A KCT-45L 45 90 107 32 42 100-800A KCT-60L 60 107 120 32 42 100-1500A Product Description 1.Open current transformer Open/Open circuit 100-800A 0.5S 100/5 150/5 200/5 250/5 300/5 Three-phase AC high p...
... Of Accuracy: 1.0 (see table) ·Rated Voltage: 600V (see table) ·Rated Sec. Current 5A(or 1A on request) ·Security Factor: FS5 ·Working Temperature Range: -20℃~+45℃ ·ABS plastic case, toally enclosed, ......