| Sign In | Join Free | My burrillandco.com |
|
... Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.1/0.2/0.5 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes ......
... Friendly, Measurement Process And Instrument Working State Prompts Clear Enough, Without Operator Memory Too Much Procedures; Linear Current Compensation Technology, Test Stability, High Accuracy, High Spee...
... 4. Compact size Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-872 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA B...
...Current Transformer Parameters Size(mm) Input current (A) Output Power(mW) 55*65*5 10 13mW min 55*75*10 5 38mW min 55*75*12 5 45mW min 48*68*15 5 50mW min 55*75*20 3 45mW min parameter: SIZE Input Current Tu...
...Current Transformer Parameters Size(mm) Input current (A) Output Power(mW) 55*65*5 10 13mW min 55*75*10 5 38mW min 55*75*12 5 45mW min 48*68*15 5 50mW min 55*75*20 3 45mW min parameter: SIZE Input Current Tu...
100-3000A 50/60Hz Clamp-on Current Transformer Current Transformer / Open type CY-QCT01 Feature: 1. Divisible top , high precision and little wastage 2. Nice appearance , small volume , little weight and easy t...
100-3000A 50/60Hz Clamp-on Current Transformer Current Transformer / Open type CY-QCT01 1. Product Introduction: This type CT is designed for easy installation in tight spaces and environment without removing t...
...COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R(Ω) Reactive (±3+0.003*100/X)%·X(Ω) Test voltage: 2KV One minute Customization is available. Feature 1) Work as se...
...COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R(Ω) Reactive (±3+0.003*100/X)%·X(Ω) Test voltage: 2KV One minute Customization is available. Feature 1) Work as se...
...50mm AC Current Probe clamp transformer MODEL Q50B Custom AC Permalloy Current Probe 1000A / 5A for Ethernet Power Meter The Q50A is a 1000 Amp current probes which can measure 0-1000A cable while measuring ...
...50mm AC Current Probe clamp transformer MODEL Q50B Custom AC Permalloy Current Probe 1000A / 5A for Ethernet Power Meter The Q50A is a 1000 Amp current probes which can measure 0-1000A cable while measuring ...
...current transformer High Dielectric Current Transformer Price for Solar Inverter Product Description 1. Plastic Case 2. Accuracy 0.1 Class, very low phase error 3. Big through hole, easy to fix and install 4...
...current transformer PBT Case Current Transformer for ASD 100A 10mA Product Description 1. Plastic Case & Lead wire with plug 2. Accuracy 0.1 Class, very low phase error 3. Big through hole, easy to fix and i...
...-1:2007, IEC 61869-2:2012, Specification: Rated transformation ratio(A) Rated output(VA) SAT-30B SAT-30 SAT-40 SAT-60 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 15/5 2.5 5 20/5 2.5 5 30/5 2.5 5 40/5 2.5 5 50/5 5 10 75/...
Current Transformer Magnetic Permalloy Core Toroidal Wide Range Current Transformer Magnetic Permalloy Toroidal Core Parameters Size(mm) Input current (A) Output Power(mW) 55*65*5 10 13mW min 55*75*10 5 38mW mi...
Current Transformer Magnetic Permalloy Core Toroidal Wide Range Current Transformer Magnetic Permalloy Toroidal Core Parameters Size(mm) Input current (A) Output Power(mW) 55*65*5 10 13mW min 55*75*10 5 38mW mi...
... PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-T500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤...