... products meet the standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13. 2. Specification Type Rated transformation ratio(A) Accuracy Classes combination Accuracy class and rated output COSØ=0.8 1s thermal ...
...,P2 primary terminals,S1,S2 secondary terminals P1&S1 same as P2,S2(subtractive polarity). 2. Technical Parameter 1) Rated Primary Current: 5-3000A; Rated Secondary Current: 5A, 1A 2). Rated voltage:...
...Current Transformer Indoor Ring Type LMZJ1-0.5 1. Introduction LMZJ1-0.5/0.66 Current Transformer is used indoor, be suitable for rated voltage 0.5/0.66kV, it is widely used for measuring current, electric e...
... voltage 110kV power system, for energy measurement, current measurement and relay protection purposes. 2.Introduction to Structure LB6-110 type current transformer has an oil-immersed fullysealed structure....
... Current Transformer , 600/5A Power Miniature Current Transformer Description: Model NO.: LM-0.5 Type: Current Transformer Operation Condition: Indoor Insulating Medium: Insulating Paper Magnetic Circuit Str...
...Transformer Testing Equipment High Accuracy CT/PT Standard Current Transformer Product Description The device can test transformer with accuracy level lower than two or two less level than this device. Techn...
...Transformer Testing Equipment High Accuracy CT/PT Standard Current Transformer Product Description The device can test transformer with accuracy level lower than two or two less level than this device. Techn...
...Current Transformer Indoor High Permeability Core 1. Introduction: The current transformer is wound block type casting insulated indoor type product. It is used for measuring current,standardization,isolatio...
...Current Transformer Indoor Ring Type Plastic Case With Epoxy 1. Introduction LMZ1-0.5 Current transformer is used indoor ,be suitable for rated voltage 0.5/0.66kV,it is widely used for measuring current, ele...
...Current Transformer The current transformer of types LZZBJ9-35(D) are casting resins and fully enclosed.It is used for metering electric energy and current,relay protection in the electric system up to rated...
...Current transformer or transformator manufacturer for energy meter Product Description: MSQ Current Transformers are suitable to be applied to test, control, display and record the running of the electrical ...
...Current Transformer This series current transformer of the type LZZW-35 is casting resins and fuIly enclosed. it is used for metering electric energy and current relay protection in the electricaI system up ...
...Sensor for Low Voltage is a reliable and accurate solution for monitoring electrical currents. It features a sturdy construction that adopts high-quality PC material, ensuring durability and long-lasting per...
...Current Transformer LCZ-35Q current transformer is semi-closed insulated cast product, suitable for power metering, current measurement and relay protection in power system with rated frequency of 50Hz or 60...
...Current Transformer With Ring Core Current CYR current transformer adopts high quanlity PC materials,full-enclosed construction,round hole can pass busbar,be used for controlling,protection,measuring functio...
... metering,submetering applications,which hasSmall size,easy installation,it is safer and portable than other current transformer. Drawing Size Model I.D. Ratio Rated Amps Accuracy YM-SCT-T06 6mm 1000:1 1, 5,...
...Current Transformer For Air Conditioning A world famous MINI design plastic case current transformer, snap on body, be wildly used in generators. Rated Frequency 50/60Hz Rated test voltage 3kV AC. (1 min) Ra...
... 61869-1:2007, IEC 61869-2:2012, Specification: Rated transformation ratio(A) Rated output(VA) SAT-30B SAT-30 SAT-40 SAT-60 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 15/5 2.5 5 20/5 2.5 5 30/5 2.5 5 40/5 2.5 5 50/5 5 ...
... Of Accuracy: 1.0 (see table) ·Rated Voltage: 600V (see table) ·Rated Sec. Current 5A(or 1A on request) ·Security Factor: FS5 ·Working Temperature Range: -20℃~+45℃ ·ABS plastic case, toally enclosed, built-i...
...-5 ·High Voltage Test: 4KVeff,50Hz,1Min ·Weight: 200-250gr Rated Current(A) Primary/Secondary 30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A Accuracy Class 3 1.0 1.0 1.0 1.0 Rated Burden(VA) 1 1.5 2.5 2.5 2.5 Ou...