...Jacket 4.3mm PVC Power Wire Conductor 2x(16×0.19mmCU ) Power wire Diameter of insulation 1.8mmPVC(Red,Black) Jacket 7.75×6.35mm PVC Common Application For Use in Longer CCTV Run Lengths Electrical Characteri...
...Jacket 4.3mm PVC Power Wire Conductor 2x(24×0.19mmCU ) Power wire Diameter of insulation 2.0mmPVC(Red,Black) Jacket 7.95×6.45mm PVC Common Application For Use in Longer CCTV Run Lengths Electrical Characteri...
...Jacket 5.0mm PVC Power Wire Conductor 2x(16×0.19mmCU ) Power wire Diameter of insulation 1.8mmPVC(Red,Black) Jacket 8.3×6.5mm PVC Common Application For Use in Longer CCTV Run Lengths Electrical Characterist...
...Jacket 5.0mm PVC Power Wire Conductor 2x(32×0.19mmCU ) Power wire Diameter of insulation 2.2mmPVC(Red,Black) Jacket 8.7×6.55mm PVC Common Application For Use in Longer CCTV Run Lengths Electrical Characteris...
...±0.1mm PVC Power Wire Conductor 2x( 10*0.12mmCCA ) Power wire Diameter of insulation 0.91mmHDPE (Red,Black) Jacket 3.0mmPVC Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Co...
...%) Jacket 6.0mmPVC Power Wire Conductor 2x(10*0.12mmCCA ) Power wire Diameter of insulation 0.91HDPE(Red,Black) Jacket 3.0mmPVC Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inne...
... Aluminum Tube Shield Thickness 0.024I"/0.61mm Jacket 0.570"/14.48mm PE Jacket Thickness 0.030"/0.76mm Messenger 0.109" /2.77mm Steel Max.Breaking Strength of Messenger(kgf) 816 Application For Use in Longer...
...Smooth Aluminum Tube Shield Thickness 0.023"/0.58mm Jacket 0.625"/15.86mm PE Jacket Thickness 0.030"/0.76mm Messenger 0.109"/2.77mm Max.Breaking Strength of Messenger(kgf) 816 Application For Use in Longer C...
...Smooth Aluminum Tube Shield Thickness 0.030"/0.76mm Jacket 0.685"/17.40mm PE Jacket Thickness 0.030"/0.76mm Messenger 0.109"/2.77mm Max.Breaking Strength of Messenger(kgf) 816 Application For Use in Longer C...
... Smooth Aluminum Tube Shield Thickness 0.025" /0.63mm Jacket 0.765" /19.43mm PE Jacket Thickness 0.030"/0.76mm Messenger 7× (0.066"/1.67mm) Max.Breaking Strength of Messenger(kgf) 1769 Application For Use in...
...Smooth Aluminum Tube Shield Thickness 0.034" /0.86mm Jacket 0.820" /20.83mm PE Jacket Thickness 0.030"/0.76mm Messenger 7×(0.066"/1.67mm) Max.Breaking Strength of Messenger(kgf) 3016 Application For Use in L...
... Aluminum Tube Shield Thickness 0.023"/0.58mm Jacket 0.625"/15.86mm PE Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The...
... Aluminum Tube Shield Thickness 0.030"/0.76mm Jacket 0.685"/17.40mm PE Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The...
... Smooth Aluminum Tube Shield Thickness 0.025" /0.63mm Jacket 0.765" /19.43mm PE Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resis...
... Smooth Aluminum Tube Shield Thickness 0.034" /0.86mm Jacket 0.820" /20.83mm PE Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resis...
...%) Jacket 6.0mmPVC Power Wire Conductor 2x(10*0.12mmCCA ) Power wire Diameter of insulation 0.91HDPE(Red,Black) Jacket 3.0mmPVC Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inne...
... PE Black Jacket Thickness 0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <10.76 Ω/km Capacitance 50 ± 3 pF/m ......
... 13.72mm Welding Aluminum Tube Jacket 15.49mm PE Black Jacket Thickness 0.89mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be ...
... PE Black Jacket Thickness 0.89mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.90 Ω/km Capacitance 50 ± 3 pF/m Impedance ......
...10.03mm PE Black Jacket Thickness 0.76mm Messenger 2.11mm Steel Wire Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <10.76 Ω/km Capacitance 50 ± 3 pF/m ......