| Sign In | Join Free | My burrillandco.com |
|
... 19.94mm PE Black Jacket Thickness 0.89mm Messenger 4.78mm Steel Wire Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.90 Ω/km Capacitance 50 ± 3 pF/m Impedance ......
... 24.38mm PE Black Jacket Thickness 1.27mm Messenger 4.78mm Steel Wire Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.33 Ω/km Capacitance 50 ± 3 pF/m Impedance ......
... Polyproylene Shield 2 Bare Copper braid wire 95% coverage Diameter Over Shielding: 5.1 mm/0.20" Jacket 0.262±0.006"/6.65±0.15mmPVC Flame Retardation: IEC 60332-1 Jacket Thickness Application For Use in Long...
... Shield 2 Aluminum braid wire 95% coverage Jacket 0.268"±0.006"/6.81±0.15mm PVC Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resis...
... braid wire 95% coverage Jacket 0.238"±0.006"/6.05±0.15mm PVC CM Jacket Thickness 0.032"/0.81mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. ...
... braid wire 95% coverage Jacket 0.238"±0.006"/6.05±0.15mm PVC CMR Jacket Thickness 0.032"/0.81mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max....
... 95% coverage Jacket 0.238"±0.006"/6.05±0.15mm PVC CMR Jacket Thickness 0.032"/0.81mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ sha...
... braid wire 95% coverage Jacket 0.193"±0.006"/4.90±0.15mm PVC CMP Jacket Thickness 0.032"/0.81mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max....
... braid wire 60% coverage Jacket 0.400"±0.006"/10.16±0.15mm PE Jacket Thickness 0.042"/1.07mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at ...
... PET Shield 2 Aluminum braid wire 60% coverage Jacket 0.400"±0.006"/10.16±0.15mm PVC CMR or CMG Jacket Thickness 0.042"/1.07mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner...
...PET Shield 2 Aluminum braid wire 90% coverage Flooding Compound Jelly Jacket 0.400"±0.006"/10.16±0.15mm PE Jacket Thickness 0.042"/1.07mm Application For Use in Longer CATV Run Lengths Electrical Characteris...
... SPE Shield 0.10mm×5×16 BC Braid(L=16) Jacket 2.9±0.4mmPVC Jacket Thickness 0.04mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall ...
... SPE Shield 0.12mm×6×16 BC Braid(L=20) Jacket 4.0±0.5mmPVC Jacket Thickness 0.05mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall ...
... SPE Shield 0.14mm×6×25 BC Braid(L=26) Jacket 5.4±0.5mmPVC Jacket Thickness 0.08mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall ...
... SPE Shield 0.14mm×6×25 BC Braid(L=26) Jacket 5.4±0.5mmPVC Jacket Thickness 0.08mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall ...
... 3.1mm SPE Shield 0.14mm×6×25 BC Braid(L=26) Jacket 5.4±0.5mmPVC Jacket Thickness 0.08mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ ...
... SPE Shield 0.14mm×7×24 BC Braid(L=42) Jacket 7.6±0.5mmPVC Jacket Thickness 0.09mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall ...
... Shield 2 Aluminum braid wire 60% coverage Shield 3 Aluminum Laminated Tape(Non-bonded) Flooding Compound Jelly Jacket 0.400"±0.006"/10.16±0.15mm Jelly PE Jacket Thickness 0.042"/1.07mm Application For Use i...
...SPE Shield 0.14mm×7×24 BC Braid(L=42) Jacket 8.3±0.5mmPVC Jacket Thickness 0.10mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall b...
...SPE Shield 0.14mm×7×24 BC Braid(L=26) Jacket 8.3±0.5mmPVC Jacket Thickness 0.10mm Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall b...