| Sign In | Join Free | My burrillandco.com |
|
...Current Transformer with Current Generator HLB-40G Features 1) High accuracy 2) 5 to 4000A current transformer design 3) Used for precision measurement of calibration of instrument CT 4) Adopting advanced te...
...Current Primary Injection Tester Transformer Busbar Temperature Rise Test Bench General Information: DDG Series High Current Primary Injection Tester is a specialized device for high-current testing (e.g., t...
...Security factor: FS<5 ● Maximum system voltage: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated se...
...Security factor: FS<5 ● Maximum system voltage: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated se...
... Bridge and double-arm Bridge. It adopts the advanced starting power constant current source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperatu...
... on high-end testing technology, large-scale electronic circuit design and in compliance with relevant national regulations. Features 1. The instrument also has a recursive method to measure the current tran...
...COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R(Ω) Reactive (±3+0.003*100/X)%·X(Ω) Test voltage: 2KV One minute Customization is available. Feature 1) Work as se...
...COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R(Ω) Reactive (±3+0.003*100/X)%·X(Ω) Test voltage: 2KV One minute Customization is available. Feature 1) Work as se...
... that the current on-load tap-changers of power transformers are backward in the measurement methods, without the dedicated measurement means. It can timely diagnose the potential faults of the on-load tap-c...
The standard current transformer, functioning as a calibration device, is used to verify the accuracy of current transformers with two or fewer levels of precision below it. A current transformer consists of a ...
...P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency altern...
...Test Of Transformer AC DC Oil Type Hipot Tester With Digital Meter Introduction Hipot Tester is applied in power system for insulation test of high voltage equipment. The typical application of the HIPOT tes...
...Current Transformer Zero Single Phase Features: 1. Circuit requirements: a. Frequency: 50 - 60Hz b. Rated voltage: AC 660V 2. Production standard: IEC185 3. To test, control, display and record the operation...
...Current Transformer Zero Single Phase Features: 1. Circuit requirements: a. Frequency: 50 - 60Hz b. Rated voltage: AC 660V 2. Production standard: IEC185 3. To test, control, display and record the operation...
... On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grad...
... researched and developed based on integrated tester for volt-ampere characteristic transformation ratio and polarity of instrument transformer for voltage regulator, voltage booster and large current genera...
... researched and developed based on integrated tester for volt-ampere characteristic transformation ratio and polarity of instrument transformer for voltage regulator, voltage booster and large current genera...
Product details Multi-Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output Product Description ZXYZ-2002 Transformer On Load Tap Switch Tester is mainly used for measuring transformer on-lo...