| Sign In | Join Free | My burrillandco.com |
|
4.3-10 Male to 4.3-10 Male 1/2" Superflex RF Feeder Cable / Corrugated Low PIM Microwave Coaxial Cable 1.Inner Conductor:Smooth Copper Tube/ Copper Coating Aluminum/ Helix Copper Tube 2.Dielectric:Physical Foam...
1-1/4" 5/4" RF Coaxial cable , Telecom Aluminum Feeder Cable Characteristics Low Attenuation, low VSWR,High expansion, high power rating,Excellent environmental performance and Mechanical Performance. Standard ...
1/4" Helical Corrugated Copper Tube RF 50 ohm coaxial cable NO.7101101 Construction Parameters: Inner Conductor 1.90±0.05mm Copper Clad Aluminum Wire Insulation 4.70±0.20mm Foamed ......
3/8" Super flexible Helical Corrugated Copper Tube RF 50 ohm coaxial cable NO.7101103 Construction Parameters: Inner Conductor 2.60±0.05mm Copper Clad Aluminum Wire Insulation 6.70±0.20mm Foamed ......
3/8" Annular Corrugated Copper Tube RF 50 ohm coaxial cable NO.7101104 Construction Parameters: Inner Conductor 3.30±0.05mm Copper Clad Aluminum Wire Insulation 8.30±0.20mm Foamed ......
1-1/4" RF Corrugated 50 ohm coaxial cable NO.7101112 Construction Parameters: Inner Conductor 13.10±0.10mm Smooth Copper Tube Insulation 32.30±0.25mm ......
1-1/4" AL RF Corrugated 50 ohm coaxial cable NO.7101113 Construction Parameters: Inner Conductor 13.10±0.10mm Smooth Copper Tube Insulation 32.30±0.25mm ......
1-5/8" RF Corrugated 50 ohm coaxial cable NO.7101114 Construction Parameters: Inner Conductor 17.30±0.15mm Corrugated Copper Tube Insulation 42.50±0.30mm ......
1-5/8" AL RF Corrugated 50 ohm coaxial cable NO.7101115 Construction Parameters: Inner Conductor 17.30±0.15mm Corrugated Copper Tube Insulation 42.50±0.30mm ......
5D-FB BC TC PE 50 Ohm coaxial cable NO.7101403 Construction Parameters: Inner Conductor 1.800.03mm Bare Copper Dielectric 4.950.15mm Foamed PE Shield Bonded AL-Foil Outer Conductor Nom. 5.70mm Tinned Copper B...
7D-FB BC TC PE 50ohm Coaxial Cable NO.7101405 Construction Parameters: Inner Conductor 2.60mm Bare Copper Dielectric 7.30mm Foamed PE Shield Bonded AL-......
8D-FB BC TC PE 50 ohm coaxial cable NO.7101408 Construction Parameters: Inner Conductor 2.80±0.03mm Bare Copper Dielectric 7.80±0.15mm Foamed PE Shield ......
PK75-4-318 COAXIAL CABLE Construction Parameters: Inner Conductor 1.02mm0.02mm Copper Dielectric 4.60mm0.10 Foamed PE Shield 1 Cu/PET Shield 2 CuSn braid wire 63% coverage Outer sheath 6.800.20mm PVC *Notes ...
PK75-4-320 COAXIAL CABLE Construction Parameters: Inner Conductor 1.02mm±0.02mm Copper Dielectric 4.60mm±0.10 Foamed PE Shield 1 AL/PET ......
PK75-4-351 COAXIAL CABLE Construction Parameters: Inner Conductor 1.02mm0.02mm Copper Dielectric 4.60mm0.10 Foamed PE Shield 1 Cu/PET Shield 2 CuSn braid wire 42% coverage Outer sheath 6.800.20mm PVC *Notes ...
75-4-11 Outdoor PE 75 Ohm CATV coaxial Cable NO.7100385 Construction Parameters: Inner Conductor 0.72 mm Cu Dielectric 0.18"/4.60mm FPE Shield 96/ 0.15mm CCAM Jacket 7.0mm PE black Jacket Thickness 0.90mm App...
19 VATC CCS 75 Ohm CATV coaxial Cable NO.7100424 Construction Parameters: Inner Conductor 0.040"/1.02mm/18 AWG CCS Dielectric 0.181"/4.6mm Foamed PE Shield 1 0.187"/4.75mm Bonded Aluminum PET Shield 2 Aluminum ...
KX 6 Cu 90% Cu PVC 75 Ohm CATV coaxial Cable NO.7100432 Construction Parameters: Inner Conductor 70.008"/70.2mm/732 AWG Cu Dielectric 0.15"/3.7mm Solid PE Shield Copper (90%) Jacket 6.100.10mm PVC Applicati...
RG59/U +2C18AWG CM Common 75 Ohm CCTV coaxial Cable NO.7102024 Construction Parameters: Inner Conductor 0.032"/0.81mm/20AWG Bare Copper Dielectric 0.144"/3.660.05mm Foamed Polyethylene Shield 0.12mmBC-Braid(95...
RG59/U +2C0.75 Figure 8 75 Ohm CCTV coaxial Cable NO.7102032 Construction Parameters: Inner Conductor 0.032"/0.81mm/20AWG Bare Copper Dielectric 0.144"/3.66±0.05mm Foamed ......