| Sign In | Join Free | My burrillandco.com |
|
...Testing Equipment Standard: CECS 21: 2000 Technical specification for inspection of concrete defects by ultrasonic method ASTM D6760 Standard Test Method for Integrity Testing of Concrete Deep Foundations by...
...wires and cables - Scraping test method for extruded outer sleeves". Scope of application: Suitable for the scratch and abrasion resistance test of 30mm~80mm plastic outer jackets of cables. It is a pro...
...Test UL 9540A Introduction: Battery fire test is a test method used to evaluate the flame retardancy and safety of batteries. The safety of batteries is judged by observing their performance in a combustion ...
...Testing Machine Standards: Complies with the requirements of GB1408.1, IEC60243-1 "Test Methods for Electrical Strength of Solid Insulation Materials - Tests at Power Frequency", GB1408.2, IEC60243...
...test of twisted flexible cables used in wind power generation systems or similar systems with a rated voltage of 1.8/3kV and below in low-temperature environments. Ii. Compliance with Standards TICW1-2009 Te...
...Testing Machine GB12666.6 ZY6014G Fire Resistance Scope of application: It is suitable for testing mineral insulated cables and fire-resistant properties of cables with refractory layers. Meet the standard: ...
...surface of the combustible substrate is tested, and it is also applicable to the determination of the flame resistance time of the flamefaced fire retardant coating Meet the standard: GB/T12441-2005 (appendi...
... sterilization test method is the best method for filtering drugs. The product was filtered through a 0.45 or 0.2 micron membrane filter according to the USP sterility test method. The filter is then rinsed...
...-2008 "test method for the test method for the combustion performance of hard foam plastics". Meet the standard: Standard GB/t8333-2008 "test method for the combustion performance of hard foam plastics - ver...
... resilience of solid rubber from measurement of the vertical rebound of a dropped mass. This test method is not applicable to the testing of cellular rubbers or coated fabrics. Resilience is determined as th...
...General application — Thermal ageing methods’ clause 8.2 and 8.3 ; IEC 60335-1 ‘Household and similar electrical appliances – Safety – Part 1: General requirements’ clause 22.32; Application: It is suitable ...
...Test Equipment Thermal Ageing Oven with 1000L Volume Temperature range RT+10℃-200℃ Standard: IEC 60811-11-2 ‘Common test methods for insulating and sheathing materials of electric and optical cables — Part 1...
...30.4 IEC60811-1-4 ‘Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature’ Application: This device i...
... resilience of solid rubber from measurement of the vertical rebound of a dropped mass. This test method is not applicable to the testing of cellular rubbers or coated fabrics. Resilience is determined as th...
...Method ASTM D323 7" Touch Screen High Precision Dual Bomb PRODUCT DESCRIPTION ASTM D323 Fully Automatic Saturated Vapor Pressure Tester for Petroleum Products (Reid Method) The SH8017B automatic vapor p...
... to the standard GB 29753-2013 “Safety Requirements and Test Methods for Refrigerated Vehicles for Road Transport of Food and Biological Products”. It is used to inpsect whether the assembly of the body, doo...
... Testing Equipment , Box vertical drop Tester Machine Design Standards: GB/T 2423.38-2005,IEC 60068-2-18:2000Part 2-18
...Test Apparatus Softening Point Tester for Bitumen Summary The softening point test equipment is designed and made as per GB/T4507 Standard Test Methods for Softening Point of Petroleum Asphalt of National St...
... Test Kit Summary This asphalt penetrometer is designed and made as per T0604-2011 Penetration Test for Bituminous Materials in JTG E20-2011 Standard Test Methods for Bitumen and Bituminous Mixtures for High...
...test method is used for fire technical modelling. The data from the test results can be used for modelling bigger fires. A fire sequence in the ISO 9705 – Room Corner Test and EN 13823 – SBI can for example ...