...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 45A Current - Collector Pulsed (Icm) - Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 22A Power - Max 122W Switching Energy - ...
... Standard Gate Charge 97nC Td (on/off) @ 25°C 24ns/250ns Test Condition 400V, 10A, 20 Ohm, 15V Reverse Recovery Time (trr) 68ns Operating Temperature -40°C ~...
...IGBT Type NPT Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 12A Current - Collector Pulsed (Icm) 24A Vce(on) (Max) @ Vge, Ic 3V @ 15V, 6A Power - Max 89W Switching Energy 3...
... Type Standard Gate Charge 83nC Td (on/off) @ 25°C 92ns/1.1µs Test Condition 480V, 20A, 100 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 40A Current - Collector Pulsed (Icm) 80A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 20A Power - Max 167W Swi...
... Standard Gate Charge 95nC Td (on/off) @ 25°C 22ns/165ns Test Condition 400V, 20A, 15 Ohm, 15V Reverse Recovery Time (trr) 62ns Operating Temperature -40°C ~...
... Standard Gate Charge 140nC Td (on/off) @ 25°C 30ns/175ns Test Condition 400V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
... Standard Gate Charge 38nC Td (on/off) @ 25°C 30ns/230ns Test Condition 400V, 10A, 47 Ohm, 15V Reverse Recovery Time (trr) 90ns Operating Temperature -55°C ~...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 49A Current - Collector Pulsed (Icm) 196A Vce(on) (Max) @ Vge, Ic 1.7V @ 15V, 27A Power - Max 160W Switching Energy...
... Standard Gate Charge 95nC Td (on/off) @ 25°C 19ns/160ns Test Condition 400V, 20A, 15 Ohm, 15V Reverse Recovery Time (trr) 60ns Operating Temperature -40°C ~...
... Standard Gate Charge 28nC Td (on/off) @ 25°C 23ns/93ns Test Condition 960V, 5A, 50 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 17A Current - Collector Pulsed (Icm) 68A Vce(on) (Max) @ Vge, Ic 2.1V @ 15V, 12A Power - Max 45W Switching Energy 3...
... Standard Gate Charge 120nC Td (on/off) @ 25°C 17ns/194ns Test Condition 400V, 20A, 14.6 Ohm, 15V Reverse Recovery Time (trr) 112ns Operating Temperature -40°C ~...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 28A Current - Collector Pulsed (Icm) 56A Vce(on) (Max) @ Vge, Ic 2.7V @ 15V, 16A Power - Max 100W Switching Energy ...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 120A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 30A Power - Max 258W Sw...
... Type Standard Gate Charge 170nC Td (on/off) @ 25°C -/235ns Test Condition 600V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -40°C ~ 175°C (TJ)...
... Standard Gate Charge 100nC Td (on/off) @ 25°C 34ns/110ns Test Condition 480V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 120A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 30A Power - Max 260W Sw...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 140A Vce(on) (Max) @ Vge, Ic 2.4V @ 15V, 40A Power - Max 278W Switching Energy...
... Standard Gate Charge 95nC Td (on/off) @ 25°C 19ns/160ns Test Condition 400V, 20A, 15 Ohm, 15V Reverse Recovery Time (trr) 60ns Operating Temperature -40°C ~...