| Sign In | Join Free | My burrillandco.com |
|
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 100A Current - Collector Pulsed (Icm) 200A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 50A Power - Max 333W...
...IGBT Type NPT Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 43A Current - Collector Pulsed (Icm) 80A Vce(on) (Max) @ Vge, Ic 2.4V @ 15V, 11A Power - Max 298W Switching Ener...
... Standard Gate Charge 120nC Td (on/off) @ 25°C 30ns/140ns Test Condition 480V, 25A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 30A Current - Collector Pulsed (Icm) 120A Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 15A Power - Max 156W Switching Energ...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 1350V Current - Collector (Ic) (Max) 40A Current - Collector Pulsed (Icm) 80A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 20A Power - Max 250W Switching Energy...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 100A Current - Collector Pulsed (Icm) 100A Vce(on) (Max) @ Vge, Ic 2.4V @ 15V, 25A Power - Max 349...
... Type Standard Gate Charge 135nC Td (on/off) @ 25°C -/140ns Test Condition 400V, 40A, 10 Ohm, 15V Reverse Recovery Time (trr) 465ns Operating Temperature -55°C...
... Type Standard Gate Charge 106nC Td (on/off) @ 25°C 44ns/166ns Test Condition 400V, 60A, 5 Ohm, 15V Reverse Recovery Time (trr) 346ns Operating Temperature -55°C ~...
... Standard Gate Charge 50nC Td (on/off) @ 25°C 41ns/104ns Test Condition 400V, 24A, 10 Ohm, 15V Reverse Recovery Time (trr) 89ns Operating Temperature -55°C...
... Type Standard Gate Charge 220nC Td (on/off) @ 25°C -/200ns Test Condition 600V, 30A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -40°C ~...
... Type Standard Gate Charge 102nC Td (on/off) @ 25°C 46ns/182ns Test Condition 400V, 50A, 6 Ohm, 15V Reverse Recovery Time (trr) 327ns Operating Temperature -55°C ~...
... Standard Gate Charge 93nC Td (on/off) @ 25°C 32ns/362ns Test Condition 600V, 15A, 41.8 Ohm, 15V Reverse Recovery Time (trr) 300ns Operating Temperature -40°C ~ 175°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 240A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 60A Power - Max 375W Sw...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 50A Current - Collector Pulsed (Icm) 200A Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 25A Power - Max 192W...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 125A Vce(on) (Max) @ Vge, Ic 2.7V @ 15V, 20A Power - Max 200W Switching Energy...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 24A Current - Collector Pulsed (Icm) 96A Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 15A Power - Max 104W Switching Energy ...
...IGBT Type PT Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 150A Vce(on) (Max) @ Vge, Ic 3.5V @ 15V, 30A Power - Max 300W Switching Ener...
... Type Standard Gate Charge 145nC Td (on/off) @ 25°C 26ns/66ns Test Condition 300V, 50A, 5.9 Ohm, 15V Reverse Recovery Time (trr) 100ns Operating Temperature -55°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 107A Current - Collector Pulsed (Icm) 150A Vce(on) (Max) @ Vge, Ic 1.85V @ 15V, 50A Power - Max 366...
... Type Standard Gate Charge 160nC Td (on/off) @ 25°C 71ns/150ns Test Condition 720V, 28A, 5 Ohm, 15V Reverse Recovery Time (trr) 90ns Operating Temperature -55°C ~...