| Sign In | Join Free | My burrillandco.com |
|
... Standard Gate Charge 12nC Td (on/off) @ 25°C 11ns/60ns Test Condition 400V, 1.5A, 100 Ohm, 15V Reverse Recovery Time (trr) 85ns Operating Temperature -55°C ~...
... Standard Gate Charge 19nC Td (on/off) @ 25°C 17ns/72ns Test Condition 390V, 5A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C (TJ)...
... Type Standard Gate Charge 225nC Td (on/off) @ 25°C -/235ns Test Condition 600V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -40°C ~...
... Type Standard Gate Charge 234nC Td (on/off) @ 25°C -/245ns Test Condition 600V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -40°C ~...
... Type Standard Gate Charge 223nC Td (on/off) @ 25°C 19ns/197ns Test Condition 400V, 40A, 7.9 Ohm, 15V Reverse Recovery Time (trr) 124ns Operating Temperature -40°C...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 450V Current - Collector (Ic) (Max) 23A Current - Collector Pulsed (Icm) - Vce(on) (Max) @ Vge, Ic 1.25V @ 4V, 6A Power - Max 150W Switching Energy - I...
... Standard Gate Charge 100nC Td (on/off) @ 25°C 54ns/110ns Test Condition 480V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) 42ns Operating Temperature -55°C ~...
... Standard Gate Charge 75nC Td (on/off) @ 25°C 41ns/104ns Test Condition 400V, 24A, 10 Ohm, 15V Reverse Recovery Time (trr) 89ns Operating Temperature -55°C ~...
...IGBT Type NPT, Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 75A Current - Collector Pulsed (Icm) 105A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 40A Power - Max...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 420V Current - Collector (Ic) (Max) 30A Current - Collector Pulsed (Icm) 40A Vce(on) (Max) @ Vge, Ic 1.7V @ 4.5V, 10A Power - Max 150W Switching Energy...
...IGBT Type Trench Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 100A Current - Collector Pulsed (Icm) 200A Vce(on) (Max) @ Vge, Ic 1.7V @ 15V, 50A Power - Max 223W Switching ...
... Type Standard Gate Charge 95nC Td (on/off) @ 25°C -/145ns Test Condition 400V, 48A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 175°C (TJ)...
...IGBT Type NPT Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 120A Vce(on) (Max) @ Vge, Ic 2.55V @ 15V, 35A Power - Max 308W Switching Ene...
...IGBT Type Trench Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 50A Current - Collector Pulsed (Icm) 60A Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 20A Power - Max 180W Switching E...
... Standard Gate Charge 115nC Td (on/off) @ 25°C 27ns/277ns Test Condition 600V, 25A, 23 Ohm, 15V Reverse Recovery Time (trr) 290ns Operating Temperature -40°C...
... Type Standard Gate Charge 79nC Td (on/off) @ 25°C 16ns/93ns Test Condition 600V, 20A, 5 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
... Type Standard Gate Charge 203nC Td (on/off) @ 25°C 16ns/122ns Test Condition 600V, 25A, 4.3 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~...
... Standard Gate Charge 120nC Td (on/off) @ 25°C 27ns/265ns Test Condition 600V, 25A, 16.4 Ohm, 15V Reverse Recovery Time (trr) 195ns Operating Temperature -40°C ~ 175°C (TJ)...
... Standard Gate Charge 53nC Td (on/off) @ 25°C 20ns/90ns Test Condition 600V, 20A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 175°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 120A Current - Collector Pulsed (Icm) 240A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 80A Power - Max 469W...