... Type Standard Gate Charge 310nC Td (on/off) @ 25°C 26ns/299ns Test Condition 400V, 50A, 7 Ohm, 15V Reverse Recovery Time (trr) 143ns Operating Temperature -40°C ~ 175°C...
...IGBT Type Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 150A Current - Collector Pulsed (Icm) 225A Vce(on) (Max) @ Vge, Ic 2.4V @ 15V, 75A Power - Max 452W Switch...
... Standard Gate Charge 140nC Td (on/off) @ 25°C 85ns/222ns Test Condition 400V, 75A, 10 Ohm, 15V Reverse Recovery Time (trr) 90ns Operating Temperature -40°C...
... Type Standard Gate Charge 95nC Td (on/off) @ 25°C -/145ns Test Condition 400V, 48A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 175°C (TJ)...
... Type Standard Gate Charge 180nC Td (on/off) @ 25°C 87ns/140ns Test Condition 800V, 24A, 5 Ohm, 15V Reverse Recovery Time (trr) 90ns Operating Temperature -55°C ~...
... Type Standard Gate Charge 225nC Td (on/off) @ 25°C 18ns/250ns Test Condition 400V, 30A, 6.8 Ohm, 15V Reverse Recovery Time (trr) 35ns Operating Temperature -55°C ~...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 120A Current - Collector Pulsed (Icm) 240A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 80A Power - Max 469W...
... Type Standard Gate Charge 155nC Td (on/off) @ 25°C 22ns/280ns Test Condition 800V, 25A, 1 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C (TJ)...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 120A Current - Collector Pulsed (Icm) 240A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 80A Power - Max 469W...
... Type Standard Gate Charge 340nC Td (on/off) @ 25°C 34ns/54ns Test Condition 480V, 60A, 5 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
... Standard Gate Charge 195nC Td (on/off) @ 25°C 52ns/240ns Test Condition 390V, 40A, 10 Ohm, 15V Reverse Recovery Time (trr) 55ns Operating Temperature -55°C ~...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 70A Current - Collector Pulsed (Icm) 105A Vce(on) (Max) @ Vge, Ic 2.2V @ 15V, 35A Power - Max 368W...
... Standard Gate Charge 13nC Td (on/off) @ 25°C 18ns/110ns Test Condition 400V, 3A, 100 Ohm, 15V Reverse Recovery Time (trr) 77ns Operating Temperature -55°C ~...
... Type Standard Gate Charge 340nC Td (on/off) @ 25°C 24ns/230ns Test Condition 800V, 50A, 4.7 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C (TJ)...
... Standard Gate Charge 15nC Td (on/off) @ 25°C 76ns/815ns Test Condition 480V, 8A, 100 Ohm, 15V Reverse Recovery Time (trr) 28ns Operating Temperature -55°C ~...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 160A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 40A Power - Max 283W Sw...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 400V Current - Collector (Ic) (Max) - Current - Collector Pulsed (Icm) 150A Vce(on) (Max) @ Vge, Ic 7V @ 2.5V, 100A Power - Max - Switching Energy - In...
... (off) Input Type Standard Gate Charge - Td (on/off) @ 25°C 690ns/12.1µs Test Condition 960V, 5A, 1 kOhm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C (TJ)...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 60A Current - Collector Pulsed (Icm) 120A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 30A Power - Max 258W Sw...
... Gate Charge 18.2nC Td (on/off) @ 25°C 25ns/215ns Test Condition 400V, 5A, 100 Ohm, 15V Reverse Recovery Time (trr) 70ns Operating Temperature -55°C ~...