...Transformer Testing Equipment High Accuracy CT/PT Standard Current Transformer Product Description The device can test transformer with accuracy level lower than two or two less level than this device. Techn...
...Current Clamp On Current Transformer Ratio 500A / 5V 2.5 Meter Cable The GFUVE Q40-2 Split Core Current Sensor has high frequency available for oscilloscope, excellent linearity performance. The distinct jaw...
...Current Transformer for I-P close link meter ratio 1:1 KE6322 Isolation current transformer KE6322 is a two phase 1:1 current transformer, which mainly used to test I-P close link meter. It has high accuracy...
... accuracy level. It is composed of primary winding and secondary winding. When wiring, strictly refer to the current ratio given by the wiring board for wiring. L1 and K1 are the polar ends of the primary an...
Standard CT Rated primary current : 5A-1000A,5A-2000A,5A-3150A,5A-5000A (or other rated primary current value ) Reference value of rated primary current (A): 5,7.5,10,12.5,15,20,25,30,40,50,60,75,80,100,120,125...
...Current Transformer Test Set for Portable Reference Standard Features & Functions Can be used for on-site verification of current and electromagnetic type voltage transformer ratio difference and difference,...
...Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard according with:IE...
... error and phase displacement of current transformers. Standard: IEC 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers Current Transformer Testing Equipment configura...
...single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power sou...
...-1:2007, IEC 61869-2:2012, Specification: Rated transformation ratio(A) Rated output(VA) SAT-30B SAT-30 SAT-40 SAT-60 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 15/5 2.5 5 20/5 2.5 5 30/5 2.5 5 40/5 2.5 5 ......
...Current transformer: Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: 5A-300A 5A,1A VDE0414,BS7626...
... transformer and voltage transformer at rated burden and working burden in one time test. CPT-I Current Transformer Tester can automatically evaluate the test results according to the selected standard to de...
...Current Split Core Current Transformer 1.Main Features: ● 500A Split Core Current Transformer ● High Reliability via High Accuracy ● Easy Assembly,"0" Cost "0" Destroy ● Well-matched to Measuring & Control U...
...6kA Mainly using for: Clamp-on current transformer Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided i...
... and they can help to measure the current or protect the equipment. Type Rated current ratio Accuracy class Circle diameter (mm) 0.5 class 1 class K-Φ24 (150-200)A/5(1)A 1 1 Φ24 (250-300)A/5(1)A 1.5 1 K-Φ36 ...