immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker

    Buy cheap immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker from wholesalers
     
    Buy cheap immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker from wholesalers
    • Buy cheap immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker from wholesalers

    immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker

    Ask Lasest Price
    Brand Name : Zecen
    Model Number : cTnI
    Certification : CE, ISO13485
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000 Set/Sets per Month
    Delivery Time : 15 workdays
    • Product Details
    • Company Profile

    immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker

    CLIA Reagents of Inflammation (cTnI)


    【Expected usage】

    For the quantitative detection of troponin I (cTnI) in human serum in vitro. Cardiac troponin (cTn) (including cTnI and cTnT) in acute coronary
    It also has important clinical implications in the risk stratification of ACS. When the myocardial cell membrane is intact, cTnI and cTnT cannot penetrate the cell membrane and enter the blood circulation, so the blood of healthy people does not contain or contain very low amounts of cTnI and cTnT. , cTnT diffused into the interstitium and appeared earlier in peripheral blood. Cardiac troponin appears earlier (3-12 hours) after the onset, lasts for a long time (4-10 days), and has high sensitivity and specificity for myocardial injury. It is currently the best definite marker for the diagnosis of AMI thing.


    Troponin I is a specific and sensitive marker for detecting myocardial injury. Elevated levels of troponin (above the cutoff value) within 4-12 hours of acute myocardial ischemia have high specificity and sensitivity for the diagnosis of acute myocardial infarction. According to the ESC and ACC Common Protocol - Redefinition of Myocardial Infarction (which gives the definition of myocardial infarction and the reliability of cTnl assays), AMI is defined as: Troponin I concentration exceeding the 99% confidence interval of the reference control group Any case of standard thresholds. Therefore, the acceptable (total) imprecision at the 99% confidence interval for each assay should be defined as: no more than 10%. Troponin concentrations peak within 14-36 hours of acute infarction and remain high for 7 days. Serial testing of troponin I concentrations is recommended in patients with suspected myocardial injury.


    At the same time, cTnI is the preferred marker for risk stratification, and if feasible, all patients with suspected ACS should be tested for cTn. In patients with clinical symptoms consistent with ACS, a peak cTn value above the 99th percentile of the normal reference population is predicted to be at increased risk of death and recurrence of ischemic events.


    The current clinical and laboratory determination methods for troponin I include enzyme-linked immunosorbent assay, colloidal gold method, fluorescence immunoassay, and chemiluminescence method.


    【Inspection Principle】

    This kit adopts the principle of direct sandwich method, uses magnetic microparticles as the solid phase of immune reaction, and uses chemiluminescence enzyme-linked immunoassay method and chemiluminescence measuring instrument to detect the content of cTnI in human serum.


    The technical principle is: Fluorescein isothiocyanate (FITC)-labeled mouse monoclonal anti-cTnI antibody and alkaline phosphatase (AP)-labeled paired mouse monoclonal anti-cTnI antibody and samples, calibrators or quality controls. cTnI binds to form a "sandwich" complex. Subsequently, the magnetic particles linked with goat anti-fluorescein isothiocyanate (FITC) antibody were added, and the antigen-antibody immune complexes were bound to the magnetic particles through the specific binding of the anti-FITC antibody to FITC.


    Under the action of an external magnetic field, the complex formed by the immune reaction is separated from other unbound substances, and after washing the complex, an enzymatic chemiluminescent substrate (adamantane derivative) is added. The substrate is catalytically cleaved under the action of the enzyme to form an unstable excited state intermediate.


    When the excited state intermediate returns to the ground state, photons are emitted to form a luminescence reaction, and the luminescence intensity of the reaction can be detected by a chemiluminescence instrument. In the range of measured wavelength (230-700nm), the luminescence intensity is proportional to the content of cTnI in the sample, and the cTnI concentration in the sample can be calculated by fitting the modified four-parameter Logistic equation.


    Test ItemcTnI
    Luminescent PrincipleEnzymatic chemiluminescence
    Luminescent MarkersAP(alkaline phosphatase)
    Specification100 Test/Kit for CIA series
    /
    PrincipleSandwich method
    ComponentMagnetic Beads
    Calibrator Low
    Calibrator High
    Anti-A/Anti-B
    Control 1
    Control 2
    Accessories Required But Not ProvidedSubstrate
    Washing solution
    Sample materialSerum
    Storage2-8℃




    Quality immunoassay test kit Serum assay kit Cardiac Troponin I (cTnI) for Automatic immunoassay analyzer in Cardiac Marker for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Taizhou Zecen Biotech Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more In Vitro Diagnostic Reagents products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0