Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

    Buy cheap Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box from wholesalers
     
    Buy cheap Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box from wholesalers
    • Buy cheap Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box from wholesalers

    Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

    Ask Lasest Price
    Brand Name : Zecen
    Model Number : CLIA, POClia
    Certification : ISO 13485, CE, FSC,
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 T/Month/Project
    Delivery Time : 10 Days
    • Product Details
    • Company Profile

    Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

    Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

    INTENDED USE

    The kit has been designed for the quantitative determination of Pepsinogen II (PG II) in human serum.

    The method can be used for samples over the range of 0.5-150.0 ng/mL.

    The test has to be performed on the CIA fully auto analyzer (Including CIA 600, CIA 1200, CIA 1800, CIA2800).


    KIT COMPONENTS

    Material Supplies

    Reagent Integral for 50 determinations
    Magnetic beads: TRIS buffer, magnetic beads complex binding with goat anti-FITC, buffer with BSA1×1.5mL
    Calibrator Low:BSA buffer with low level of PGII antigen1×0.15mL
    Calibrator High:BSA buffer with high level of PGII antigen1×0.15mL
    PGII Anti A: PGII Antibody complex labeled FITC, containing buffer with BSA1×3.0mL
    PGII Anti B: PGII Antibody complex labeled by AP, containing buffer with BSA1×3.0mL
    All reagents are provided ready-to-use.

    Reagent Integral for 100 determinations
    Magnetic beads: TRIS buffer, magnetic beads complex binding with goat anti-FITC, buffer with BSA1×3.0mL
    Calibrator Low:BSA buffer with low level of PGII antigen1×0.15mL
    Calibrator High:BSA buffer with high level of PGII antigen1×0.15mL
    PGII Anti A: PGII Antibody complex labeled FITC, containing buffer with BSA1×6.0mL
    PGII Anti B: PGII Antibody complex labeled by AP, containing buffer with BSA1×6.0mL
    All reagents are provided ready-to-use.

    Reagent Vials in kit box
    Control 1: BSA buffer with low level of PGII Antigen1×0.15 mL
    Control 2: BSA buffer with high level of PGII Antigen1×0.15 mL
    target value refer to Quality Control sheet

    Accessories Required But Not Provided

    SubstrateREF: SR2001
    System Washing solutionREF: WR2001
    Probe Washing SolutionREF: WR2002

    product compositionTwo points: LH
    Six points: ABCDEF
    Testing method1. Treat the calibrator as the sample to be tested, and place it in the sample loading area of the instrument after mixing. Note that when mixing Avoid air bubbles.
    2. During the detection, the system detects the luminescence value (RLU value) of each calibration point, and calculates the luminescence value according to the nominal concentration and luminescence value.
    The calibration curve is automatically fitted by the instrument. In order to ensure the reliability of the calibration curve, the determination of the calibrator should be
    Make a double.
    3. The generated calibration curve can be used for 28 days, but it should be re-calibrated after the following conditions:
    ① Change of batch number of supporting testing reagents;
    Change of batch number of luminescent substrate
    ②The measured value of the quality control product is not within the scope of quality control or the test results are inconsistent with the clinical situation;
    ③System for major repairs or maintenance.
    Interpretation of test results1. For reasons such as methodology or antibody specificity, the same sample was tested using reagents from different manufacturers.
    Testing with different reagents may give different test results, therefore, the results obtained by testing with different reagents should not be directly
    They are compared with each other in order to avoid false medical interpretations.
    2. The quality control product can be used as a reference for the reliability of the current experimental results, and its measured value should be within the
    within the range allowed by the quality control sheet. Test results should be based on reference value ranges and other clinical factors and results
    Comprehensive judgment, when the test result is close to the upper limit or lower limit of the reference value range, it can be considered
    samples for confirmation testing.
    Storage and expiration dateStored at 2-8°C, the product is valid for 12 months. Reagents should be used within 1 month after opening, and stored at 2-8°C away from direct sunlight.

    Quality Tumor Marker PGII Pepsinogen II for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Taizhou Zecen Biotech Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more In Vitro Diagnostic Reagents products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0