Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.

2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

 

Why does a coil get burnt when removed from valve?

This is because with AC 50/60Hz coils you are reducing the impedance or resistance of the coil, as the shading ring within the armature or stem generates resistance within the coil. By removing the coil whilst powered the resistance is reduced thus the power consumption can easily increase above the coil winding class limits causing over heating.

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry! 

" }
Sign In | Join Free | My burrillandco.com
Home > Hardware Stock >

8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil

    Buy cheap 8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil from wholesalers
     
    Buy cheap 8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil from wholesalers
    • Buy cheap 8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil from wholesalers
    • Buy cheap 8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil from wholesalers

    8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil

    Ask Lasest Price
    Brand Name : BRANDO
    Model Number : BB08029101
    Certification : None
    Payment Terms : T/T, PayPal, Western Union
    Supply Ability : 100000pcs per month
    Delivery Time : Negotiation
    Price : Negotiation
    • Product Details
    • Company Profile

    8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil

    8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil


    Applicable Industries:Solenoid Valve
    Type:Fittings
    Place of Origin:Zhejiang, China
    Brand Name:Brando
    Hole Size:8mm
    Height:29mm
    Width:19.6mm
    Voltage:24V DC, 24V AC, 110V AC, 230V
    Power:5VA
    Connection Type:DIN43650B
    Insulation class:F, H
    Protection class:IP65, IP67, IP68
    Application:6011, 6012 Solenoid Valve

    Dimension of 6012/6011 Type Solenoid Valve Coil :

    Dimension of 6012/6011 Type Solenoid Valve Coil :

    Technical Data:

    Model
    BB08029101
    Hole size
    8mm
    Height
    29mm
    Width
    19.6mm
    Voltages
    DC24V, Ac24V, AC110V, AC220V
    Power
    5VA
    Insulation class
    F, H
    Connection Type
    DIN43650B
    Application examples
    6011, 6012 Solenoid Valve

    Details:

    D2d3d4
    Hole size 8.0mmHeight 29.0mmWidth 19.6mm

    Solenoid Coil Production Line:


    Attention:
    1. This air suspension compressor pump solenoid coil is made of high quality components.

    2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
    3. Please double confirm the compatibility as well as the OEM number before purchasing.
    4. Instruction is not included. Professional installation is recommended.


    Why does a coil get burnt when removed from valve?

    This is because with AC 50/60Hz coils you are reducing the impedance or resistance of the coil, as the shading ring within the armature or stem generates resistance within the coil. By removing the coil whilst powered the resistance is reduced thus the power consumption can easily increase above the coil winding class limits causing over heating.


    Steps and methods for properly installing a solenoid valve coil:

    1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

    2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

    3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

    4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

    5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

    6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

    7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.


    Focus on your demands, Offer you best solution:


    √ Contact us if some points you have doubt
    √ Contact us if somewhere need to change
    √ Contact us if not the one you are looking for
    √ Contact us if you are doing designing


    Welcome to your any question and inquiry!

    Quality 8mm Hole Diameter DIN43650B 6011 6012 Plunger Solenoid Valve Coil for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Solenoid Valve Coil products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0