Sign In | Join Free | My burrillandco.com
Home >

BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil

    Buy cheap BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil from wholesalers
     
    Buy cheap BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil from wholesalers
    • Buy cheap BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil from wholesalers
    • Buy cheap BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil from wholesalers

    BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil

    Ask Lasest Price
    Brand Name : BRANDO
    Model Number : BB15045054
    Certification : None
    Price : Negotiation
    Payment Terms : T/T, PayPal, Western Union
    Supply Ability : 250000 pieces per month
    Delivery Time : Negotiation
    • Product Details
    • Company Profile

    BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil

    BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil


    Solenoid Valve Coils (DC) and Electrical Polarity
    A common question about solenoid valve coils is whether the electrical current polarity matters in a DC coil. Most coils with lead wires use the same color wire for both terminals and have no polarity markings. The answer is that polarity does not matter. You can connect the positive terminal to either of the two wires without affecting the operation of the valve.


    Technical parameter of Copper refrigeration solenoid valve coils:

    Model NumberBB15045054
    Normal voltageAC220V; DC24V; or OEM
    Normal powerAC:25VA DC16W
    Insulation classH
    Connection typeDIN43650A
    ApplicationEVR refrigeration solenoid valve series
    Net Weight487.5 g

    Main dimension of 15 mm hole diameter of refrigeration electromagnetic valve coils:


    Three type EVR refirgeration solenoid valve series acessories for you to choose:


    Factory display of AC220V/DC24V refrigeration system solneoid valve coils:


    The main purpose of automation is to optimize the performance of the refrigeration system, including:

    • Use an expansion valve to control the injection of liquid refrigerant into the evaporator.


    • Use the accumulator to compensate for changes in the level of the condenser.


    • Use a solenoid valve with coils to control the flow of liquid to the evaporator.


    • Protect the system with a safety device to prevent pressure from being too low or too high.


    • Use oil separators to minimize oil entry into the system.


    • Use a dry filter to prevent damage from moisture and contaminants in the system.


    • Use a sight glass to prevent excess or insufficient refrigerant in the system and check the refrigerant condition.


    • Minimize repair time with shut-off valves or ball valves.


    • Use a pressure regulator to maintain system temperature and pressure at the low and high pressure ends.


    • Increase system efficiency with expansion valves, oil separators, and condensing pressure controllers.


    Main parts and accessories for automated refrigeration systems:

    1. The copper tube is a capillary tube and acts as a throttling;
    2. The solenoid valve acts as a control flow no matter where it is. The on/off of the coil determines the switch of the solenoid valve.


    The vapor compression refrigeration system consists of the following components to form a closed system. The system is filled with refrigerant, which is driven by the compressor to circulate in the system pipeline, and absorbs heat through the evaporator and the condenser to release heat to achieve the cooling function.


    (1) Compressor: The compressor used in the conventional refrigerator is a reciprocating piston type totally enclosed compressor;


    (2) Condenser: The condenser of the refrigerator is cooled by natural convection by air, and the refrigerant vapor is condensed into a liquid, and the condensers are respectively placed inside the tank walls on both sides of the refrigerator cabinet.


    (3) Evaporator: The evaporator is a component in which the refrigerant evaporates to produce a cooling effect, and has a refrigerating compartment evaporator and a freezer compartment evaporator. The refrigerator compartment evaporator is attached to the foam layer side of the rear wall of the refrigerator compartment, and the freezer compartment evaporator is directly fixed in the freezer compartment tank.


    (4) Capillary: The capillary is an elongated copper tube that acts as a throttling mechanism in the refrigeration system.


    (5) Drying filter: It is placed between the condenser and the capillary to absorb moisture.


    Welcome to your inquiry!

    Quality BG380AS 018F6803 EVR Refrigeration Solenoid Valve Replacement Coil for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Solenoid Valve Coil products from this supplier
    Inquiry Cart 0